Re: LoadRunner 12.00 Released!
You are welcome to post any technical questions and feedback in the LoadRunner Support Forum.
View ArticleRe: Urgent Help - ALNUM in correlation function.
I got this resolved using "RB/ALNUMIC" instead of "RB/DIG"
View ArticleVUGEN LRVUG_00044
Hi experts. I'd like to know where I can possibly find LRVUG_00044. Thank you for any help you can give. :)
View ArticleRe: VUGEN LRVUG_00044
Hi, You can download it from the following link :http://support.openview.hp.com/selfsolve/document/KM00209457 Kind regards, Vesela
View ArticleRe: LR Support Tip-LoadRunner/Performance Center 12.01 and 12 patch 1 are...
Hi,Do you know if, in future, there will be an upgrade instead of a full release ? (We have already installed PC12.0 / ALM12.0 / LR12.0, and patch 1...)
View ArticleRe: failed - end event error due to network timeout
Did anyone get this issue resolved? I am having a similar issue with both protocols, TruCLient IE and Firefox.
View ArticleRe: LR Support Tip-LoadRunner/Performance Center 12.01 and 12 patch 1 are...
Hello,It doesn't really matter if you have a patch-like installation or a full package installation for the product. The upgrade process works in both cases. You don't need to uninstall anything you...
View ArticleRe: LoadRunner 12 / Load Generator Unix/Linux
So are you saying that LR 12 CE does not work on Linux?
View ArticleRe: Load runner Controller issues with chrome
Hi, Do you see the problem for all vusers, or only for some of them?If it's seen only for some part of vusers, then the problem is probably caused by the high SSL connection rate.You Web server cannot...
View ArticleRe: LR Support Tip-LoadRunner/Performance Center 12.01 and 12 patch 1 are...
hello,nice ! thank you for your response Igor !
View ArticleIssue with Flex Protocol based scripts
Hi , While running a scenario in LR Controller , I am getting errors for one of the script.I have ran the same scenario many times, the exception never appeared. I am not sure it is because of the...
View ArticleRe: Citrix issue
Hi Can you please provide us more info about what is happening . Did you get any error? Do you see that connetion with citrix server is establish? did you install Citrix Register client patch? Did you...
View ArticleRe: Unable to Get Complete Analysis Report
Thanks for the response Chau. I followed as HP LR Analysis/ Tools/ Option/ Result Collection , under Date Time Range , I selected 'Entire Scenario' .The above helped. Regards,Era
View ArticleExpert day is today ( July 29th), challenge our experts !
Hi all, Challenge our experts ! If you are a customer with a support contract, then we would like to invite you to join us in LoadRunner Support Customer Forum on July 29th when HP product Experts will...
View ArticleRe: Issue with Flex Protocol based scripts
hi, Please add the FlexJvmParams="-Xmx512m" entry shall to the %LR_PATH%\dat\flex_ro.ini file, under the [FLEX_RO] section.You can specify a lower / higher value of max heap size if needed. Regards,Roy
View ArticleRe: Issue with Flex Protocol based scripts
Thanks for the response Roy. I already have FlexJvmParams=-Xmx2048m at Flex_ro.ini file of loadrunner . Still facing the issue. Looking forward for solution. Regards,Era
View ArticleRe: Issue with Flex Protocol based scripts
If this error happens during replay on the LG, then you might need to modify the FlexJvmParams in <script>\default.cfg Or if you don't do any correlations in the failing step, then you might...
View ArticleRe: failed - end event error due to network timeout
Such issues usually happen due to incorrect timings/pacing (Script replay is too fast and needs to be slowed down) or incorrect end events of steps.I suggest using multiple "Wait for Object" steps to...
View ArticleRe: Issue with Flex Protocol based scripts
Hi, Which LoadRunner version are you using?How many vusers are you running? Regardless of my previous questions, the following steps may help:Please add JavaOOMThreshold=400000 under the [Flex] section...
View ArticleLoadrunner cannot connect Load Generator,for help!
I add a new LoadGenerator in Windows Server 2008, close the firewall ,add start the Agent Process.But I cannot connect this LoadGennerator in Contrallor machine.When I click connect ,it will prompt...
View Article